Item Name | Capacitor Fixed Electrolytic |
INC Code | 00008 |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5910 Capacitors |
National Item Identification Number (NIIN) | 01-245-6442 (012456442) |
NCB Code | USA (01) |
Manufacturer | Kemet Electronics Corporation, Holt Instrument Laboratories Llc, Selex Es Limited, Canberra Industries Inc, Xerox Corporation, Selex Communications Inc, Honeywell International Inc, Lockheed Martin Corporation, Union Carbide Corp, Raytheon Company |
Associated Parts Numbers of NSN 5910-01-245-6442 |
||||||
---|---|---|---|---|---|---|
Part Number | Manufacturer | Item Name | Cage Code | Type | Status | RFQ |
K33C10K | kemet electronics corporation | capacitor fixed electrolytic | 31433 | A | A | RFQ |
0905-101 | holt instrument laboratories llc | capacitor fixed electrolytic | 09435 | F | A | RFQ |
117002-0011 | selex es limited | capacitor fixed electrolytic | 64415 | A | A | RFQ |
43750-15 | canberra industries inc | capacitor fixed electrolytic | 06442 | A | A | RFQ |
123300-336 | xerox corporation | capacitor fixed electrolytic | 18338 | A | F | RFQ |
6L.5275.040.00-441527 | selex communications inc | capacitor fixed electrolytic | d0327 | E | A | RFQ |
14000117-005 | honeywell international inc | capacitor fixed electrolytic | 17479 | F | A | RFQ |
7903069-11 | lockheed martin corporation | capacitor fixed ele | 90536 | A | A | RFQ |
T310B336K010AS | union carbide corp | capacitor fixed electrolytic | 05397 | A | F | RFQ |
K33C10K | union carbide corp | capacitor fixed electrolytic | 05397 | A | F | RFQ |
SCM336BP006A2 | raytheon company | capacitor fixed electrolytic | 96214 | A | A | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | WO MTG FACILITIES AXIAL TERMINALSWO MTG FACILITIES AXIAL TERMINALSWO MTG FACILITIES AXIAL TERMINALS |
AARF | MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | N-4 |
AARG | RELIABILITY INDICATOR | ESTABLISHEDESTABLISHEDESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 1 0001 0001 000 |
ABJT | TERMINAL LENGTH | 1 500 INCHES NOMINAL1 500 INCHES NOMINAL1 500 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0 185 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0 474 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0 020 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | ELECTRODES GROUNDED TO CASE WGND TERMINAL |
AECE | ANODE TYPE | SOLID |
AECQ | ELECTRICAL POLARIZATION | POLARIZED |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
CQBQ | CAPACITANCE VALUE PER SECTION | 33 000 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55 0 DEG CELSIUS MINIMUM AND 85 0 DEG CELSIUS MAXIMUM |
CQLH | DC LEAKAGE AT MAXIMUM OPERATING TEMP | 50 0 MICROAMPERES |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 10 0 DC SINGLE SECTION |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CRTP | TOLERANCE RANGE PER SECTION | -10 0010 00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | METAL |
CWNJ | CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 6 000 |
CWQH | DC LEAKAGE AT REFERENCE TEMP | 2 500 MICROAMPERES |
CWSZ | CASE INSULATION MATERIAL | PLASTIC |
FEAT | SPECIAL FEATURES | WEIBULL GRADED FAILURE RATE |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-39003 SPECIFICATION INCLUDES ENGINEERING TYPE BULLETINS BROCHURESETC THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT EXCLUDES COMMERCIAL CATALOGS INDUSTRY DIRECTORIES AND SIMILAR TRADE PUBLICATIONS REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
ZZZK | SPECIFICATIONSTANDARD DATA | 81349-MIL-C-390031 GOVERNMENT SPECIFICATION |
Relevant Components for NSN - 5910-01-245-6442, 5910012456442 |
||||
5935-01-388-2680 (5935013882680) | 5930-01-595-2299 (5930015952299) | 5998-01-174-6938 (5998011746938) | 5945-01-043-9783 (5945010439783) | |
5998-00-249-1833 (5998002491833) | 5961-00-883-6931 (5961008836931) | 5998-00-703-7746 (5998007037746) | 5935-00-499-6169 (5935004996169) | |
5965-01-377-3587 (5965013773587) | 5945-01-552-9002 (5945015529002) | 5930-01-187-6003 (5930011876003) | 5960-01-613-6120 (5960016136120) | |
Guaranteed on-time |
|
Customized and |
|
Over 5100 |
|
Complete Purchasing |
We Hope You'll Choose Us to Fulfill Your AOG Needs In the Future. We’Re Always Ready to Serve, 24/7, 365 Days A Year.
Request for Quote