ASAP Semiconductor appreciates your request for quotation sent via JetParts360.com for part number 1526-016-10 made by Manufacturer Eaton Corp with it's corresponding NSN 5925009358702, CAGE Code 76374 and FSC 5925 Circuit Breakers. This 1526-016-10 part is described as Circuit Breaker. You can expect a response from a dedicated customer service expert from ASAP Semiconductor within 15 minutes. Each RFQ is answered in the order it was received. We request you to fill out your contact information, as well as quantity, and any target price along with an expected delivery date for 1526-016-10 part. We will strive to provide you with an aggressive price to earn the opportunity for your business.
Please Fill Out Below Form
“*” Symbols for mandatory fields
You can mail your Bill of Materials (BOM) to sales@jetparts360.com. Please do not hesitate to contact us if you have any additional questions. With over 50,000 manufacturers and 20 million unique part numbers we are a one stop shop for all aerospace and aviation requirements. Feel free to browse our website, JetParts360.com for any additional parts that you might require or download the ASAP Semiconductor App on the Google Play store. We are available 24/7 at +1-714-705-4780.
5925-00-935-8702, 5925009358702 Characteristics Data
MRC
Criteria
Characteristic
AAQL
BODY STYLE
MULTIPOLE-SINGLE ACTUATOR TYPE
ABXD
BUSHING LENGTH
0 250 INCHES NOMINAL
ADAQ
BODY LENGTH
2 073 INCHES MAXIMUM
ADAT
BODY WIDTH
1 300 INCHES MAXIMUM
ADAU
BODY HEIGHT
1 921 INCHES MAXIMUM
AEBP
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
1 370 INCHES NOMINAL
AEBQ
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH
0 750 INCHES NOMINAL
AKPX
POLE QUANTITY
3
AXHR
MOUNTING FACILITY TYPE AND QUANTITY
1 THREADED BUSHING
BBRG
STORAGE TYPE
GENERAL PURPOSE WAREHOUSE
CMLP
THREAD QUANTITY PER INCH
32
CPLM
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
10 0 AMPERES AC ALL LOCATIONS
CPRF
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
200 0 AC ALL LOCATIONS
CPRG
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
2500 0 AC ALL LOCATIONS
CPRH
CIRCUIT PROTECTION TYPE
OVERCURRENT ALL LOCATIONS
CPRJ
TRIP RELEASE METHOD
THERMAL ALL LOCATIONS
CPRL
TRIP RELEASE CHARACTERISTIC
TIME DELAY ALL LOCATIONS
CPRN
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
138 0 ALL LOCATIONS
CPRQ
RESET METHOD
MANUAL
CPRR
MAIN CONTACT TRIPPING MECHANISM TYPE
TRIP FREE
CPRT
MANUAL ACTUATOR TYPE AND QUANTITY
1 PUSH-PULL
CPRW
ACTUATOR FUNCTION
TRIP-RESET
CPRX
ACTUATOR POSITION DESIGNATION
AT POLE TWO
CPSM
INTERNAL TRIP RELEASE CONFIGURATION
SERIES TRIP ALL LOCATIONS
CQJX
NOMINAL THREAD SIZE
0 469 INCHES
CQWN
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
3 000 MINIMUM AT 200 PCT AND 7 600 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXF
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
FUNGUS RESISTANT
CRCF
TRIP RELEASE AMBIENT TEMP RATING
65 0 DEG CELSIUS NOMINAL ALL LOCATIONS
CWJK
CASE MATERIAL
PLASTIC
FREQ
FREQUENCY IN HERTZ
400 0 ALL LOCATIONS
TEST
TEST DATA DOCUMENT
76301-32-76173 DRAWING THIS IS THE BASIC GOVERNING DRAWING SUCH AS A CONTRACTOR DRAWING ORIGINAL EQUIPMENT MANUFACTURER DRAWING ETC EXCLUDES ANY SPECIFICATION STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA