ASAP Semiconductor appreciates your request for quotation sent via JetParts360.com for part number TFJ226150 made by Manufacturer General Electric Company with it's corresponding NSN 5925010337887, CAGE Code 60969 and FSC 5925 Circuit Breakers. This TFJ226150 part is described as Circuit Breaker. You can expect a response from a dedicated customer service expert from ASAP Semiconductor within 15 minutes. Each RFQ is answered in the order it was received. We request you to fill out your contact information, as well as quantity, and any target price along with an expected delivery date for TFJ226150 part. We will strive to provide you with an aggressive price to earn the opportunity for your business.
Please Fill Out Below Form
“*” Symbols for mandatory fields
You can mail your Bill of Materials (BOM) to sales@jetparts360.com. Please do not hesitate to contact us if you have any additional questions. With over 50,000 manufacturers and 20 million unique part numbers we are a one stop shop for all aerospace and aviation requirements. Feel free to browse our website, JetParts360.com for any additional parts that you might require or download the ASAP Semiconductor App on the Google Play store. We are available 24/7 at +1-714-705-4780.
5925-01-033-7887, 5925010337887 Characteristics Data
MRC
Criteria
Characteristic
AAQL
BODY STYLE
MULTIPOLE-SINGLE ACTUATOR TYPE
AEBV
UNTHREADED MOUNTING HOLE DIAMETER
0 190 INCHES NOMINAL
AXHR
MOUNTING FACILITY TYPE AND QUANTITY
4 UNTHREADED HOLE
CPLM
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
150 0 AMPERES AC ALL LOCATIONS
CPRF
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
600 0 AC AND 250 0 DC ALL LOCATIONS
CPRG
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
25000 0 AC AND 10000 0 DC ALL LOCATIONS
CPRH
CIRCUIT PROTECTION TYPE
OVERCURRENT ALL LOCATIONS
CPRJ
TRIP RELEASE METHOD
THERMAL-MAGNETIC ALL LOCATIONS
CPRL
TRIP RELEASE CHARACTERISTIC
INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
CPRN
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
125 0 ALL LOCATIONS
CPRQ
RESET METHOD
MANUAL
CPRR
MAIN CONTACT TRIPPING MECHANISM TYPE
TRIP FREE
CPRT
MANUAL ACTUATOR TYPE AND QUANTITY
1 TOGGLE
CPRW
ACTUATOR FUNCTION
TRIP WSEPARATE RESET
CQWN
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
100 000 MINIMUM AT 200 PCT AND 300 000 MAXIMUM AT 200 PCT AND 50 000 MINIMUM AT 250 PCT AND 140 000 MAXIMUM AT 250 PCT AND 30 000 MINIMUM AT 300 PCT AND 80 000 MAXIMUM AT 300 PCT ALL LOCATIONS