ASAP Semiconductor appreciates your request for quotation sent via JetParts360.com for part number 203-2-2-41-252-4-1-1A made by Manufacturer Sensata Technologies Inc with it's corresponding NSN 5925011652919, CAGE Code 81541 and FSC 5925 Circuit Breakers. This 203-2-2-41-252-4-1-1A part is described as Circuit Breaker. You can expect a response from a dedicated customer service expert from ASAP Semiconductor within 15 minutes. Each RFQ is answered in the order it was received. We request you to fill out your contact information, as well as quantity, and any target price along with an expected delivery date for 203-2-2-41-252-4-1-1A part. We will strive to provide you with an aggressive price to earn the opportunity for your business.
Please Fill Out Below Form
“*” Symbols for mandatory fields
You can mail your Bill of Materials (BOM) to sales@jetparts360.com. Please do not hesitate to contact us if you have any additional questions. With over 50,000 manufacturers and 20 million unique part numbers we are a one stop shop for all aerospace and aviation requirements. Feel free to browse our website, JetParts360.com for any additional parts that you might require or download the ASAP Semiconductor App on the Google Play store. We are available 24/7 at +1-714-705-4780.
5925-01-165-2919, 5925011652919 Characteristics Data
MRC
Criteria
Characteristic
AAQL
BODY STYLE
SINGLE POLE TYPE
ADAQ
BODY LENGTH
2 000 INCHES NOMINAL
ADAT
BODY WIDTH
0 920 INCHES NOMINAL
ADAU
BODY HEIGHT
1 770 INCHES MAXIMUM
AEGJ
SWITCH CONTACT ARRANGEMENT
SINGLE POLE DOUBLE THROW
AJEC
BOSS HEIGHT
0 125 INCHES NOMINAL
AKPX
POLE QUANTITY
1
AXHR
MOUNTING FACILITY TYPE AND QUANTITY
2 CLIP
CPLM
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
2 5 AMPERES AC SINGLE LOCATION
CPRF
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
250 0 AC SINGLE LOCATION
CPRG
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
1000 0 AC SINGLE LOCATION
CPRH
CIRCUIT PROTECTION TYPE
OVERCURRENT SINGLE LOCATION
CPRJ
TRIP RELEASE METHOD
MAGNETIC-HYDRAULIC SINGLE LOCATION
CPRL
TRIP RELEASE CHARACTERISTIC
TIME DELAY SINGLE LOCATION
CPRN
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
125 0 SINGLE LOCATION
CPRP
ULTIMATE TRIP TIME PER POLE IN SECONDS
0 200 MINIMUM AND 7 000 MAXIMUM SINGLE LOCATION
CPRQ
RESET METHOD
MANUAL
CPRR
MAIN CONTACT TRIPPING MECHANISM TYPE
TRIP FREE
CPRT
MANUAL ACTUATOR TYPE AND QUANTITY
1 TOGGLE
CPRW
ACTUATOR FUNCTION
TRIP-RESET
CPRX
ACTUATOR POSITION DESIGNATION
AT POLE ONE
CPRZ
AUXILIARY SWITCH FUNCTION AND QUANTITY
1 ALARM
CPSM
INTERNAL TRIP RELEASE CONFIGURATION
SERIES TRIP SINGLE LOCATION
CQSM
SWITCH LOCATION AND POSITION DESIGNATION
EXTERNAL AT POLE ONE
CQWN
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
0 050 MINIMUM AT 200 PCT AND 0 950 MAXIMUM AT 200 PCT AND 0 020 MINIMUM AT 400 PCT AND 0 240 MAXIMUM AT 400 PCT AND 0 130 MAXIMUM AT 600 PCT AND 0 060 MAXIMUM AT 800 PCT SINGLE LOCATION